Cosmo de México exhibe en el Foro de Proveeduría Automotriz, Stand #359, Pabellón JETRO — del al , Poliforum León
Skip to Content
Capable and Versatile

LS-1866

The LS‑1866 is not only compact and lightweight, but also a simple and easy to use air leak tester. Compact size body with the latest functions, such as master preset, multi-channel and mL/min leak rate display, etc.

Equipped with a highly sensitive / high pressure resistant DP sensor as well as a heat-resistant air controlled valve. The basic circuit, a high performance and exceptionally safe intelligent air circuit, performs checks of valve operation and sensor sensitivity during each test. The master presetting function and the NR mode function enable improved detection capability and reduced test times. Channel functions are also available, allowing compatibility with many types of workpieces.

Probador de fugas Cosmo LS-1866
Función de preajuste maestro del Cosmo LS-1866

Prest Master

It extracts the actual leakage from drift or noise factors affecting the measurement. This function improves the production ratio and shortens the cycle time.

Clamp output

DC24V is emitted from the beginning to the end of the test. The use of this signal allows control of the clamp template by the air leak tester.

Salida de abrazadera del Cosmo LS-1866
Calibración de fugas del Cosmo LS-1866

Leakage calibration

The calibration port, located on the front panel of the air leak tester, allows easy verification of the leak rate by installing Leak Maste, etc.

Quick fixing bracket

Installation or removal of the air leak tester can be easily accomplished with only two threads.

Soporte de fijación rápida del Cosmo LS-1866

Product features


General specifications

Differential pressure
Minimum display0,1 Pa
Display range± 999 Pa
Excess pressure in the sensors5 mPa
Leakage volume display range0,00 ~ ± 999 ml/min (Automatic range)
Alarm setting range0 ~ ± 999
Timer setting range0 ~ 999.8s (Infinite setting)
Number of channelsSixteen
Power supplyAC100 ~ 240V ± 10%, 50/60Hz, 70VA max
Test pressure sourceIt uses clean air. The original pressure must be sufficiently higher than the test pressure.
Pilot pressure sourceApply 400 to 700 kPa of clean air.
Transmission functionRS-232C serial port
Ambient temperature / humidity5 to 40°C / 80% RH or less, yet no dew condensation.

¿Buscas más información técnica del LS-1866?

Descarga el catálogo completo del fabricante Cosmo Instruments.