LS-R912
The large chassis of the LS-R912, developed from the basic specifications of the LS-R900, offers the function to switch between two test pressures (Input A and Input B). The combination of the two pressures (Input A and Input B) can be selected from the nominal values table. Up to two EP regulators can be configured on the leak tester. This allows you to increase both productivity and efficiency at the cost of a single device.

Measuring screen
With the ability to change the device language from English to Japanese and Chinese, you will never again have to worry about misunderstanding certain functions and features.
Input selection screens
This allows the user to instantly select the two different inputs with just a click of a button, making it easy to modify and display the necessary data when needed.


Load-holding screens
The LS-910 makes your life easier by directly indicating whether the parts to be tested are pressurized or not. This function remains active regardless of whether the shut-off valve is open or closed.
Product features
General specifications
Intelligent pneumatic circuit II
Performance of the check valves. Pneumatic tests to verify the sensitivity of the DPS. Valve equipment. Weight reduction. High flow capacity.
Load retention
It is used to detect the location of the leak.
Calibration
Measurement of equivalent internal volume. Calibration of range K (Ve) and compensation of the differential pressure sensor. Calibration test of the range and compensation of the pressure sensor.
Leakage limits
Two-level limit configuration (DET HH, DET Hi, DET Lo, DET LL). Noise reduction.
Drift compensation
Mastering, automatic drift compensation, compensation limits, number of samples.
Self-diagnosis
Performance of the valves. Sensitivity of the pneumatic DPS system. Open/closed shut-off valve. Sensor compensation. CPU performance.
Exhaust interference prevention
Control of the exhaust timing of the pneumatic circuit units.
Sensor protection (exhaust air blowing)
Cleaning of the pneumatic circuit at the end of each test cycle.
Sensor protection (external exhaust valve)
An independent external escape valve unit (G3-M) is required.
Group
Synchronize the start and end (escape) of the selected station.
LAN port
FTP server (in preparation).
General specifications
| Differenial pressure | |
| Minimum reading | 0.1 Pa |
| Reading accuracy | ± 2.5 % of the reading ± 1 Pa. ± 2.5 % of the reading ± 1 Pa for a range above 50 Pa. ± 2 Pa for a range of 0 to 50 Pa |
| Sensor range | ± 1500 Pa |
| Test pressure | 5 mPa |
| Sensor pressure | |
| Test accuracy | mPa, kPa (PSI, kg/cm2, bar, mbar, mmHg, cmHg, inHg) *1 |
| Leakage rate | Pa, kPa, mL/s, mL/min, L/min (mmH20, inH20, mmHg, in3/min, in3/d) *1 |
| Equivalent internal volume | mL, L (in3, ft3) *1 |
| Number of stations | Up to 8 stations |
| Number of channels | 32 channels (0 ~ 31) |
Are you looking for more technical information about the LS-R912?
Download the complete catalog from the manufacturer Cosmo Instruments.