Skip to Content
easy setup

LS-R912

The large chassis of the LS-R912, developed from the basic specifications of the LS-R900, offers the function to switch between two test pressures (Input A and Input B). The combination of the two pressures (Input A and Input B) can be selected from the nominal values table. Up to two EP regulators can be configured on the leak tester. This allows you to increase both productivity and efficiency at the cost of a single device.
Cosmo LS-R912 dual pressure leak tester

Measurement display of the Cosmo LS-R912

Measuring screen

With the ability to change the device language from English to Japanese and Chinese, you will never again have to worry about misunderstanding certain functions and features.

Input selection screens

This allows the user to instantly select the two different inputs with just a click of a button, making it easy to modify and display the necessary data when needed.

Input selection display of the Cosmo LS-R912
Load retention display of the Cosmo LS-R912

Load-holding screens

The LS-910 makes your life easier by directly indicating whether the parts to be tested are pressurized or not. This function remains active regardless of whether the shut-off valve is open or closed.

Product features


General specifications

Intelligent pneumatic circuit II

Performance of the check valves. Pneumatic tests to verify the sensitivity of the DPS. Valve equipment. Weight reduction. High flow capacity.

Load retention

It is used to detect the location of the leak.

Calibration

Measurement of equivalent internal volume. Calibration of range K (Ve) and compensation of the differential pressure sensor. Calibration test of the range and compensation of the pressure sensor.

Leakage limits

Two-level limit configuration (DET HH, DET Hi, DET Lo, DET LL). Noise reduction.

Drift compensation

Mastering, automatic drift compensation, compensation limits, number of samples.

Self-diagnosis

Performance of the valves. Sensitivity of the pneumatic DPS system. Open/closed shut-off valve. Sensor compensation. CPU performance.

Exhaust interference prevention

Control of the exhaust timing of the pneumatic circuit units.

Sensor protection (exhaust air blowing)

Cleaning of the pneumatic circuit at the end of each test cycle.

Sensor protection (external exhaust valve)

An independent external escape valve unit (G3-M) is required.

Group

Synchronize the start and end (escape) of the selected station.

LAN port

FTP server (in preparation).

General specifications

Differenial pressure


Minimum reading0.1 Pa
Reading accuracy± 2.5 % of the reading ± 1 Pa. ± 2.5 % of the reading ± 1 Pa for a range above 50 Pa. ± 2 Pa for a range of 0 to 50 Pa
Sensor range± 1500 Pa
Test pressure5 mPa
Sensor pressure


Test accuracymPa, kPa (PSI, kg/cm2, bar, mbar, mmHg, cmHg, inHg) *1
Leakage ratePa, kPa, mL/s, mL/min, L/min (mmH20, inH20, mmHg, in3/min, in3/d) *1
Equivalent internal volumemL, L (in3, ft3) *1
Number of stationsUp to 8 stations
Number of channels32 channels (0 ~ 31)

Are you looking for more technical information about the LS-R912?

Download the complete catalog from the manufacturer Cosmo Instruments.