LS-R912
The large frame body of the LS-R912 developed with the basic specification of the LS-R900 offers a function to switch between 2 test pressures (Input A and Input B). The combination of the 2 pressures (Input A and Input B) can be selected from the Ratings Table. Up to two EP regulators can be configured on the leak tester. This allows you to increase both productivity and efficiency at the cost of a single device.

Measuring screen
With the ability to change the device language from English to Japanese and Chinese, you will never again have to worry about misunderstanding certain functions and features.
Input selection screens
This allows the user to select the two different entries on the fly at the click of a button, making it easy to modify and display the required data when needed.


Load-holding screens
The LS-910 makes your life easier by directly showing you whether parts to be tested are pressurized or not. This function remains active regardless of whether the shut-off valve is open or closed.
Product features
Standard features
Intelligent pneumatic circuit II
Checking valve performance. Pneumatics checking the sensitivity of the DPS. Valve equipment. Weight savings. High flow capacity.
Load retention
It is used to detect the location of the leak.
Calibration
Equivalent internal volume measurement. K (Ve) range calibration and compensation of differential pressure sensor. Range calibration and pressure sensor compensation test.
Leakage limits
Two-level limit setting (DET HH, DET Hi, DET Lo, DET LL). Noise reduction.
Drift compensation
To master, the average, fixed mobile.
Self-diagnosis
Valve performance. Pneumatics DPS sensitivity. Shut-off valve open / closed. Sensor compensation. CPU performance.
Exhaust interference prevention
Control of the exhaust timing of the pneumatic circuit units.
Sensor protection (exhaust air blowing)
Cleaning of the pneumatic circuit at the end of each test cycle.
Sensor protection (external exhaust valve)
A separate external exhaust valve unit (G3-M) is required.
Group
Sincronizar el inicio y el final (escape) de la estación seleccionada.
LAN port
FTP server (In preparation).
General specifications
| Differenial pressure | |
| Minimum reading | 0,1 Pa |
| Reading accuracy | ± 2,5% of the reading ± 1 Pa. ± 2,5% of the reading ± 1 Pa para un rango superior a 50 Pa. ± 2 Pa for a range of 0-50 Pa |
| Sensor range | ± 1500 Pa |
| Test pressure | 5 mPa |
| Presión de sensor | |
| Test accuracy | mPa, kPa (PSI, kg/cm2, bar, mbar, mmHg, cmHg, inHg) *1 |
| Leakage rate | Pa, kPa, mL/s, mL/min, L/min (mmH20, inH20, mmHg, in3/min, in3/d) *1 |
| Equivalent internal volume | mL, L (in3, ft3) *1 |
| Number of stations | Up to 8 stations |
| Number of channels | 32 channels (0 ~ 31) |