Skip to Content
Capable and versatile

LS-R902

The LS-R902 features a wide range of advanced functions that have evolved over many years of knowledge and experience. It offers numerous intuitive capabilities, such as a full-color touchscreen, waveform measurement display, an automatic setup function for easy programming, a USB port that allows data migration and import from other devices, and much more.

Cosmo LS-R902 leak tester — front view
Main setup screen of the Cosmo LS-R902

Easy-to-navigate configuration

Intuitive operation makes it easy to program test parameters.

Selectable measurement screen

You can choose from 6 different measurement screens. Four of them are: "Standard," "Simple," "Waveform," and "4 channels." The items displayed can be customized.

Measurement screen of the Cosmo LS-R902
Parameter setup menu of the Cosmo LS-R902

Setup menu

A large numeric keypad appears for easy configuration of test parameters.

Improved operability

It is convenient for faster setup operation with the quick access function.

Quick access function of the Cosmo LS-R902
Data storage via USB on the Cosmo LS-R902

Easy data storage

Test results can be automatically copied to a USB memory after each test. Test parameters and a backup of system data can also be saved.

Product features


General specifications

Screen

5.7-inch full-color LCD touchscreen. You can choose from 6 different measurement screens.

Intelligent pneumatic circuit

It comes with self-checking functions: sensor sensitivity and air valve performance.

Automatic K (Ve) configuration

K (Ve) can be configured using a calibrator, a Leak Master, or an Auto-Leak Calibrator (ALC) to convert the measured pressure into a flow rate.

Leak limits

Two sets of leak limits: medium/small leak on the working side (UL / UL2) and on the master side (LL / LL2).

Electro-pneumatic regulator

For models that come with electro-pneumatic regulator, different test pressures can be set independently for each channel.

Noise reduction (NR)

Eliminates noise when repeating the DET stage when the reading is between DET UL and DET UL2.

Download operating manual

The operating manual in each language can be downloaded via the USB port.

Drift compensation

Mastering, automatic drift compensation, compensation limits, number of samples.

Self-check

Performance of pneumatic valves, DPS/PS compensation, CPU performance, and others.

Exhaust interference prevention

Exhaust timing shall be controlled in cases where several cavities are tested simultaneosuly.

General specifications

DPS


Resolution0.1 Pa
Guaranteed accuracy range± 1000 Pa
Accuracy± 2.5 % of reading ± 1 Pa, 50 Pa or less: ± 2 Pa
Test sensor pressure5 mPa
Monitor


Accuracy of the test unitkPa, MPa (kg/cm2, psi, bar, etc.)
Leak rate unitPa, kPa, mL/s, mL/min, L/min, Pa·m3/s, E-3 Pa·m3/s, Pa/s, Pa/min, *Pa/s, *Pa/min (mmH2O, mmHg, inH2O, etc.)
Equivalent internal volume unitmL, L (in3, ft3)
Leakage screenFrom 3 to 5 digits (floating point), sampling frequency: 10 times per second
Leak limitUp to ± 999.9 Pa

Are you looking for more technical information about the LS-R902?

Download the complete catalog from the manufacturer Cosmo Instruments.