Cosmo de México exhibe en el Foro de Proveeduría Automotriz, Stand #359, Pabellón JETRO — del al , Poliforum León
Skip to Content
Capable and Versatile

LS-R740(ZL)

The LS-R740(ZL) is ideal for testing waterproof components of finished products that require IP protection rating. The part to be tested is placed in a capsule and pressurized to measure the pressure change caused by leakage flowing into the part.

Probador de fugas Cosmo LS-R740(ZL) para componentes a prueba de agua
Icono de interfaz intuitiva del Cosmo LS-R740(ZL)

Intuitive and easy-to-navigate interface with simple menu configuration.

Icono de visualización de forma de onda del Cosmo LS-R740(ZL)

Test pressure and differential pressure waveform display.

Icono de compensación de ruido del Cosmo LS-R740(ZL)

The influence of the noise generated during the test on the workpiece can be compensated, reducing the test time.

Icono de selección de idioma del Cosmo LS-R740(ZL)

Three selectable languages: English, Chinese, Japanese.

Icono de puerto USB del Cosmo LS-R740(ZL)

USB port for easy management of test data.

Icono de ubicación del sensor del Cosmo LS-R740(ZL)

Closest location of the sensor unit to the target capsule.

Product features


General specifications

Differential pressure
Resolution0,1 Pa
Display range± 999,9 Pa
Accuracy± 2.5% of the reading ± 1 Pa, 50 Pa or less ± 2 Pa
Sensor test pressure5 mPa
Unit
Test accuracykPa, MPa (kg/cm2, psi, bar, etc.)
Leakage ratePa, kPa, mL/s, mL/min, L/min, Pa·m3/s, E-3 Pa·m3/s, Pa/s, Pa/min, *Pa/s, *Pa/min (mmH2O, mmHg, inH2O, etc.)
K (Ve) leakage coefficientmL, L (in3, ft3)
Leakage screen4 digits, sampling rate: 10 times/seg.
Leakage limit999,99 maximum
No # of channels32 channels (0 to 31)
Timer999,9 seconds (resolution 0,1 segundos)
Power supplyAC100 ~ 240V ± 10%, 50/60Hz, 70VA max.
Ambient temperature5 to 45 ℃
Humidity80% relative humidity or less / no dew condensation
WeightController: approx. 2,6 kg, Pneumatic unit: approx. 7,1 kg
Pressure sourceClean, dry air. The source pressure must be sufficiently higher than the test pressure.
Pilot pressureAdjustment using the installed pilot pressure filter regulator: Range: 400 to 700 kPa
Port sizeThe special gasket is used only for the WORK and MASTER port pipes. Rc (PT) 1/4: pressure source, WORK and MASTER ports.
UPCSH-2A 144 MHz, DRAM 8 MB
RS-232CThe limit values are transmitted, as well as the large and small leakage limits. LL-DET and S-DET test results are transmitted. 4 other formats available. Trial, leakage, test pressure, channel number, timers, etc. Test the parameters of all configuration screen.
USB portM1K1, M3K4, ID2 format, L2 format, others. Test data, test parameter.

¿Buscas más información técnica del LS-R740(ZL)?

Descarga el catálogo completo del fabricante Cosmo Instruments.