Skip to Content
Capable and versatile

LS-R700

The LS-R700 is sophisticated and, at the same time, easy to use. It is simple to handle and its intuitive interface makes it easy to use and saves you time. Thanks to its waveform display, the LS-R700 can show differential pressure and test pressure in an informative format.

Cosmo LS-R700 Leak Tester
Simple and intuitive interface of the Cosmo LS-R700

Simple and intuitive

Intuitive operation makes it easy to program test parameters.

Easy-to-read measurement displays

You can choose from 3 measurement displays, depending on the situation.

Measurement displays of the Cosmo LS-R700
Complete settings menu of the Cosmo LS-R700

Complete adjustments

The configuration menu is easy to follow. The guidance bar at the bottom gives you a simple explanation of what the item is.

Product features


Standard features

Display

3.5 inch color LCD Selectable between 3 different measurement displays.

Intelligent pneumatic circuit

It comes with self-checking functions: sensor, sensitivity, air valve performance.

Automatic K (Ve) configuration

K (Ve) can be configured via Leak Master to measure the leakage coefficient and convert the measured pressure into a flow rate.

Leakage limits

Two sets of leakage limits: medium/small leakage on the working side (UL / UL2) and on the master side (LL / LL2).

Electro-pneumatic control

For models that come with an electro-pneumatic regulator, different test pressures can be set independently for each channel.

Noise reduction

Eliminate noise by repeating the DET stage when readings are between DET UL and DET UL2. (To disable the "Cycle over" setting)

Inspection and Calibration

Verification of the offset and range of the differential pressure sensor (DPS). Verification of the offset and range of the pressure sensor (PS).

Compensation

Mastering, automatic deviation compensation, fixed compensation.

Self-diagnosis

Performance of pneumatic valves, DPS/PS compensation, CPU performance, and others.

Sensor protection

Air purge (smart pneumatic circuit): the pneumatic circuit is cleaned at the end of each leak test. Ready for external exhaust valve: the valve is sold separately.

General specifications

Differential pressure


Resolution0.1 Pa
Reading accuracy± 2.5 % of reading ± 1 Pa; 50 Pa or less: ± 2 Pa ± 1500 Pa
Display range± 999,9 Pa (guaranteed accuracy: ± 1000 Pa)
Test accuracy5 mPa
Screen


Precision test unitkPa, MPa, PSI, kg/cm2, bar, mbar, mmHg, cmHg, inHg
Leakage unitPa, kPa, mL/s, mL/min, L/min, Pa·m3/s, E-3 Pa·m3/s, Pa/s, Pa/min, *Pa/s, *Pa/min, mmH2O, inH2O, mmHg, in3/min, in3/d, ft3/h
Unit K (Ve) (Leakage coefficient)mL, L, in3, ft3
Leakage screen4-digit sampling rate: 10 times/s
Leakage limit range± 999.9 Pa

Are you looking for more technical information about the LS-R700?